Rika Sensor is a weather sensor manufacturer and environmental monitoring solution provider with 10+ years of industry experience.
PRODUCT DESCRIPTION
The RK500-12-B2 stands as a paragon of precision and durability in pH monitoring technology, engineered to meet the rigorous demands of industrial, wastewater treatment, and environmental monitoring applications. This robust sensor is designed with a blend of Glass+ABS material, ensuring both chemical resistance and structural integrity, while its IP68 ingress protection rating safeguards performance in harsh, wet, or dusty environments.
Delivering exceptional measurement accuracy, the RK500-12-B2 operates across a wide 0-14pH range with a precise resolution and accuracy of 0.01pH, supported by rapid 10-second response time (achieving 98% accuracy in flowing liquid conditions). Its intelligent design incorporates thermal resistance for reliable temperature compensation, ensuring stable readings even in fluctuating thermal environments.
SPECIFICATIONS
Technical Parameter | |
Type | B2 |
Material | Glass+ABS |
Operation temperature | 0-80℃ |
Working pressure | 1Mpa |
Thread | PG13.5 |
Electrical connection | M8 waterproof connector |
Application | Industrial water, sewage, environ-mental protection, etc |
Range | 0-14pH |
Resolution | 0.01pH |
Accuracy | 0.01pH |
Response time | 10 seconds (98% flowing liquid) |
Temperature compensation | Thermal resistance |
Power supply | 7-28VDC(< 0.15W) |
Output | RS485 & 4-20mA |
Dimensions | Φ12.0 x 170.0 |
Ingress protection | IP68 |
pH Scale
pH value | Description |
<4.5 | Strongly acidity |
4.5-5.5 | Acidity |
5.5-6.5 | Faintly acidity |
6.5-7.5 | Neutral |
7.5-8.5 | Faintly alkalinity |
8.5-9.5 | Alkalinity |
>9.5 | Strongly alkalinity |
Electrode Maintenance
When the probe is not in use, it can be soaked in 3mol/l KCL solution or saturated KCL solution. It is strictly prohibited to immerse the electrode in distilled water, deionized water, or tap water with very low ion content. If the pH electrode is contaminated with inorganic substances, it can be cleaned with 0.1mol/l HCl or sodium hydroxide solution for a few minutes, and then rinsed with distilled water.If the pH electrode is contaminated with organic matter, it can be cleaned with alcohol or acetone, and then rinsed with distilled water. (Note: When using, remove the protective cap in front of the electrode)
According to the work environment, clean the electrodes with tap water every 3 or 6 months.
Installation & Fixed
Installation bracket (Iength=1m) NPT3/4 installation thread is optional