RIKA SENSOR / DATA CENTER LIQUID COOLING

RK500-12LC
Liquid Cooling pH Sensor

Online pH monitoring for liquid cooling.

RK500-12LC pH sensor with M16 connector
M16 Connector
RK500-12LC pH sensor with direct cable
Direct Cable
0-14 pHMeasurement range
±0.1 pHSpecified accuracy at 25°C
4-20 mA + RS485Simultaneous outputs
7-30 VDCSupply voltage

OVERVIEW

Track coolant acidity and alkalinity online

The RK500-12LC is designed for online pH monitoring in liquid cooling systems. It uses a low-impedance glass electrode with automatic temperature compensation.

Coolant pH shows how acidic or alkaline the liquid is. Excessive acidity can corrode metal parts in the cooling system. Online monitoring helps you follow pH changes as the coolant circulates.

APPLICATION

Keep coolant pH in view

In the conceptual diagram, a pH sensor is installed on a bypass of the coolant return pipe. The dashed line shows its signal connection to a controller. The RK500-12LC provides 4-20 mA and RS485 outputs at the same time.

Choose a location with stable flow and no obvious turbulence. A bypass makes maintenance easier. Avoid positions where gas or sediment can collect, and confirm the coolant type before ordering.

Conceptual liquid cooling loop with a CDU, server racks, bypass pH sensor and monitoring controller
Conceptual liquid cooling loop with pH monitoring on a return-line bypass.

PRODUCT FEATURES

Built for online pH monitoring

pH measurement

A low-impedance glass membrane and automatic temperature compensation support online pH measurement. Specified accuracy is ±0.1 pH at 25°C, with 0.01 pH resolution.

Protection against interference

Internal signal isolation helps reduce electrical interference. The glass membrane is resistant to hydrolysis and can be used in alkaline conditions.

Two outputs at the same time

Simultaneous 4-20 mA and RS485 outputs connect to compatible monitoring equipment. The sensor operates on 7-30 VDC and consumes less than 0.2 W.

TECHNICAL DATA

Technical Specifications

Measurement Performance

Measurement range 0-14 pH
Specified accuracy ±0.1 pHAt 25°C
Resolution 0.01 pH
Response time 10 seconds98% response in flowing liquid
Temperature compensation AutomaticThermal resistance

Electrical & Cabling

Supply voltage 7-30 VDC
Signal outputs 4-20 mA + RS485Simultaneous analog and digital outputs
Power consumption <0.2 W
Cable termination M16 connector or direct cable
Cable length 5 m standardOther cable lengths can be customized

Operating Conditions & Connections

Operating & Storage

Applicable media Deionized water, PG25 and EG25
Operating temperature 0 to +60°C
Pressure resistance 1 MPa (10 bar)
Probe ingress protection IP68
Storage temperature 10 to 60°C
Storage humidity 20%-90% RH

Materials & Process Connections

Main materials 316L stainless steel + titanium alloy
O-ring material EPDMG3/4 and NPT3/4 connections
G3/4 End-face seal
NPT3/4 Thread seal
50.5 chuck Gasket seal

Specification V5.2.0. Confirm the coolant type, concentration and material compatibility before ordering. The electrode requires KCl soaking when not in use; see the care instructions below.

INSTALLATION

Plan the installation for stable readings

Choose a stable flow location

Install on a bypass pipe for easier maintenance. Choose a location with steady flow and no obvious turbulence. Vertical upward flow is preferred; a suitable horizontal pipe is also acceptable.

Keep the pH sensor at least 15° from the horizontal line.

Keep the sensing area clear

Avoid high-point gas traps, low-point sediment zones, vertical downward flow and positions downstream of pressure-reducing sections. Bubbles and deposits can affect readings.

For the M16 connector, leave at least 70 mm of cable outlet clearance to prevent excessive bending.

ELECTRODE CARE

Care for the glass electrode

Before use

Remove the protective cap in front of the electrode before placing the sensor into service.

When not in use

Soak the electrode in 3 mol/L KCl solution or saturated KCl solution.

Do not store it immersed in distilled water, deionized water or tap water with very low ion content.

Routine cleaning

Follow the cleaning procedure in the product specification for the type of contamination present.

The specification recommends cleaning with tap water every 6 months, according to the working environment.

SPECIFY YOUR RK500-12LC

Tell Us About Your Cooling Loop

Share your coolant type and concentration, required pH range, operating temperature and pressure, process connection, and controller input requirements. Include your preferred cable connection and length, if known.

Our team can help review the process connection, cable option and sensor configuration for your cooling loop.

Contact RIKA SENSOR

E-Mail: info@rikasensor.com

After-sales Service: support@rikasensor.com

WhatsApp | WeChat  +86 13367318895

Get in touch with us
Just leave your email or phone number in the contact form so we can send you a free quote for our wide range of designs!
RIKA Sensor
Copyright © 2026 Hunan Rika Electronic Tech Co.,Ltd | Sitemap | Privacy Policy  
Customer service