Rika Sensor is a weather sensor manufacturer and environmental monitoring solution provider with 10+ years of industry experience.
Water is considered to be a source of life, and when it comes to water quality, pH is one of the most critical factors that contribute to shaping life. Maintaining the correct pH values is what drives the ecosystem and prevents catastrophic losses in terms of both lives and financial impact on industries. For example, freshwater fishes need a pH value of water to be around 6.5 to 9.0, while in hydroponic systems, crops need water that is maintained in the range of 5.5 to 6.5 to allow plants to absorb proper nutrients and grow well. Not only plants and animals need optimal pH, but humans also require drinking water to be of a pH within the range of 6.5 to 8.5, according to the World Health Organization (WHO), to ensure healthy functioning of the human body. In short, everything requires an optimal pH value to survive and grow, and any disruptions may result in damage to the environment and industries.
It's easy to keep control of pH levels once you measure them, and this is where pH sensors shine. They can provide a reliable method for measuring and monitoring pH values in real-time. With modern sensors, precision of up to ±0.01 pH units can be achieved, giving accurate readings for years and enabling quick action when imbalances occur. These sensors are what industries use to prevent losses, making them a smart and cost-effective choice for industries, researchers, and environmental monitoring alike.
Before you start measuring pH levels, the right start matters when it comes to getting accurate results. Preparation and handling may sound routine, but the proper steps taken at the beginning give precise, stable readings, free from frustrating and inaccurate readings with errors. Let’s take a look at what preparation and steps you should be considering to lay a foundation for accurate and precise results.
Care starts from the point when pH sensors are unboxed. Handle glass sensing bulbs with extreme care. This is the most sensitive part that helps provide accurate readings. Most sensors come with a protective cap and filled storage solution that helps keep the electrode hydrated and ready for use. When replacing the cap or storing the sensor, always use the recommended solution when not in use. Don’t use plain distilled or deionized water, as it would degrade the performance by removing essential ions required for accurate readings from the bulb. If, for instance, an electrode dries out, rehydrate it in a storage solution before measurements.
Modern sensors are rugged and feature waterproof connectors with an IP rating of 68 or higher, ensuring durability and reliable performance in outdoor and industrial environments. Once the connection is securely established with the data logger or monitoring device, pH levels can be observed. With a wide voltage input range (7–30 VDC) and very low power consumption, it makes it highly suitable for monitoring, especially in areas where battery-powered setups are installed. A quick power check confirms the system is ready for use.
Before installation, cleaning the sensor with deionized water is crucial to make pH sensors free from any residual or contamination that might affect readings. Instead of scrubbing or wiping the bulb, blot it dry with a lint-free tissue to protect the delicate, sensitive glass membrane. This is a step that lays the foundation for accurate results and fast response time of pH readings through sensors.
Getting accurate measurements isn’t just about turning the sensor on and getting the readings of pH values. In short, it requires more than that. Even the most advanced sensors can give readings that are unreliable if not handled properly in real-world conditions. In this section of the article, we will explore what steps or measures can be taken to ensure accurate measurements.
Once you are done with the preparation of the sensors, it's time to immerse the sensor in the sample. Accurate measurements can be achieved when the pH sensor's glass bulb and reference junction are fully submerged. Partial immersion can lead to inaccurate or incomplete readings. One common issue encountered when taking readings is the presence of air bubbles clinging to the sensing tip. This issue can restrict accurate measurements, as these bubbles form tiny barriers that disrupt contact between the electrode and the water, resulting in inaccurate or deviated readings from the actual value. To counter this issue, tap lightly or gently swirl the sensor to clear up the bubbles on the pH sensor.
Once the sensors are positioned in the right way, submerged fully in the sample, give it a moment to let it stabilize, and before record the value. In modern pH sensors, the electrodes that are used are of high quality, and they often settle quickly, reaching a stable reading in less than 30–60 seconds. When sensors are given the proper time to settle, the pH values you capture are an accurate representation of the sample you are testing.
Most modern sensors are designed to be suitable and capable of providing accurate readings across various application ranges. From beakers to test a sample to large fish farming tanks, natural streams, and industrial wastewater systems, pH sensors are designed to perform in different environmental conditions. One feature that ensures that pH sensors work effectively is automatic temperature compensation (ATC). This feature is highly crucial in ensuring that the natural shift in pH values with temperature can be countered and accurate results can be obtained, even when the temperature ranges from as warm as greenhouse water to as cold as stream water.
An effective way of measuring pH values through pH sensors in flowing water is to secure it steadily in a place to prevent turbulence that might hinder readings. Look for a sensor with a robust, waterproof housing and strong resistance to fouling to ensure consistent and accurate readings, even in demanding conditions such as wastewater channels or outdoor ponds.
Without the correct calibration, even the best sensor can fail to provide accurate readings. Over time, the electrode response tends to deviate with exposure to different samples and varying environmental conditions. This makes it essential to calibrate for precise results. In this section of the article, we will discuss the importance and the process of calibration.
pH sensors work by the interaction of glass electrodes with the solution being tested, generating a voltage. With time and continuous usage, the electrodes start aging, and the coating on the bulb begins to wear off, causing a gradual shift in readings. With calibrations, these shifts add up and result in readings that deviate from the actual value. For calibration of pH sensors, standard buffer solutions can be used to bring the sensors back to their actual values, using known values of the buffer solutions. Regular calibration is essential for applications that require high precision, such as laboratory testing, hydroponics, or water treatment systems.
The most common calibration method is two-point calibration. For pH sensor calibration using a two-point method, a neutral buffer (pH 7) and a second buffer solution, either acidic (pH 4) or alkaline (pH 10), depending on the application range, are used. Some of the applications include calibration for monitoring pH levels in fish farms or drinking water, often using pH levels of 4 and 7. On the other hand, wastewater monitoring may use pH levels of 7 and 10.
When compared to two-point calibration, three-point calibration is much favored due to its accuracy across a broader range of pH values. For three-point calibration, an acidic (pH 4), neutral (pH 7), and alkaline (pH 10) buffer is used, creating a calibration spectrum that covers a wide range of pH values from low to high with higher accuracy. This approach is widely used in industries where there is high variation in pH values.
This is how a general step-by-step calibration process for pH sensors typically looks. For improved calibration of any specific type of sensor you are choosing, follow the steps and guidelines of calibration defined by the manufacturer, or follow the user-friendly interface of modern sensors to ensure your sensor delivers results that are accurate and consistent every time.
Even with proper care and maintenance, pH sensors may experience issues or show irregular behavior. The good thing is that most of these common issues can be diagnosed and fixed with some quick checks. Below, we have identified some common problems and their fixes to help keep your pH sensor working with accurate readings.
Once the pH sensor is installed and used for some time, and if you see fluctuating values, they might not be the problem as big as you think. Some common causes of these fluctuations could be air bubbles attaching to the sensor tip. A quick fix would be to gently swirl the probe and let the sensor equilibrate with the sample. Do double-check the connection for a secure fit. Lightly rinse the sensor with deionized water to remove any residue or impurities on the pH sensor to avoid any irregularities in results.
Follow the checklist below if there are constant irregularities in readings:
These steps usually restore accuracy immediately. If not, consult the manufacturer and have a technician look at the problem to address it effectively.
With time and usage, one of the common problems faced by pH sensors is that they slowly begin to deviate from correct values, commonly referred to as drift. This mostly happens due to electrode aging or contamination. This drift can be minimized by implementing some protective and maintenance measures, such as avoiding exposure to harsh chemicals, regular cleaning with deionized water, and storing the sensor in a protective cap with a suitable storage solution. With the proper care and maintenance, pH sensors ensure consistent performance over the long run.
pH sensors are more than just a tool. When well-maintained, it is an investment in maintaining pH levels with accuracy and reliability. Ensuring proper handling, calibration, and care practices is what gives consistency in results across various applications, maximizing the sensor’s lifespan and unlocking excellent long-term value for every pH monitoring need.
LEAVE A MESSAGE