Rika Sensor is a weather sensor manufacturer and environmental monitoring solution provider since 2010
Choose a cup anemometer by matching the required wind measurements, starting threshold, measuring range and output to the site and receiving equipment. For wind direction, add a wind vane or select a combined cup-and-vane assembly. For local speed indication and warnings, consider a matched display-and-alarm system.
This guide compares RIKA SENSOR wind speed sensors, wind direction sensors, combined sensors and wind speed display controllers, helping you match the instrument to the measurements and local display or alarm functions your project needs.
Quick answer
A cup anemometer uses a rotating cup assembly to measure wind speed. The instrument relates rotor movement to wind speed through its sensing electronics and calibration relationship.
The cups respond to airflow from different horizontal directions, but their rotation does not identify where the wind comes from. A wind vane provides that separate direction measurement. This is why a cup anemometer and wind vane are often installed together.
Begin with the operational requirement: a wind-speed record for a weather station, speed and direction for site monitoring, or local speed indication with warning outputs. That choice determines which equipment needs to work together.
Use the following comparison to identify a suitable starting point. The range, output and supply must be specified for the ordered configuration.
| Model and product | Primary measurement or function | Selected specification | Selection focus |
|---|---|---|---|
| RK100-01G Wind Speed Sensor | Dedicated cup-anemometer wind speed | 0-30, 0-50 or 0-60 m/s; starting threshold 0.2 m/s | Aluminum-alloy construction and a dedicated speed channel |
| RK100-02 Wind Speed Sensor | Dedicated cup-anemometer wind speed | 0-45 m/s; starting threshold <0.5 m/s | Lightweight design and the required output option |
| RK110-01G Wind Direction Sensor | Dedicated wind direction | 0-360°; stated accuracy ±3° | A separate direction channel with an aluminum-alloy body |
| RK110-02 Wind Direction Sensor | Dedicated wind direction | 0-360°; stated accuracy ±3° | A lightweight vane and the required direction output |
| RK120-01 Combined Wind Speed and Direction Sensor | Wind speed and direction in one assembly | Speed range depends on output; direction 0-360° | Combined installation with both measurements specified |
| RK150-01 Wind Speed Display Controller | Wind speed display, warning and alarm system | Published system speed range 0-60 m/s | Local indication, configured warnings and relay functions |
When speed alone is required, choose a dedicated wind speed sensor. Add a separate wind vane for direction, select a combined sensor for both measurements in one assembly, or choose a display-controller system when operators need local speed indication and alarms.
Confirm the complete sensor-and-controller configuration when combining products. A matching connector or a familiar model name does not establish electrical or protocol compatibility.
Starting threshold describes the wind speed at which the rotating element starts to move. It is especially relevant when the project needs information about light winds.
The RK100-01G Wind Speed Sensor lists a starting threshold of 0.2 m/s, while the RK100-02 Wind Speed Sensor lists <0.5 m/s. These figures do not, by themselves, establish identical accuracy or response at the lowest readings. Include the required low-wind performance in the selection discussion.
Choose a measuring range that covers the wind conditions the project needs to record. Keep the published limit wind speed separate from that range; it is not an extension of the specified measurement range.
For the RK120-01 Combined Wind Speed and Direction Sensor, the published speed range is 0-45 m/s for current or voltage output, and 0-70 m/s for pulse, RS485 or RS232 output. The required output therefore affects range selection.
Read the entire accuracy expression. For example, the RK100-01G Wind Speed Sensor specifies ±(0.3 + 0.03v) m/s, where v is wind speed in m/s. At 10 m/s, the calculated stated limit is ±0.6 m/s. This is a specification calculation, not a field test result.
Resolution describes the reporting increment and is not the same as accuracy. A fast display update or alarm response also does not, by itself, establish how the cup rotor follows a gust. Define the averaging period and the wind event the system needs to capture.
Check operating temperature, ingress protection, connector sealing, mounting loads and the actual exposure to dust, salt, vibration or ice. An operating-temperature rating alone does not establish ice-free operation.
Choose materials for the environment and include access costs in the decision. A sensor that is difficult to reach still needs an inspection and service plan.
Select the interface from the receiving equipment's capabilities. The following options are model- and configuration-dependent.
| Interface | Receiving equipment | What to confirm | Relevant product options |
|---|---|---|---|
| Pulse | A compatible pulse counter or frequency input | Pulse level, output type, counting method and the correct wind-speed conversion | RK100-01G Wind Speed Sensor; RK100-02 Wind Speed Sensor; RK120-01 Combined Wind Speed and Direction Sensor (speed channel) |
| 4-20 mA | A compatible current input | Supply, wiring, input load and scaling for the ordered speed or direction range | Options across the speed, vane and combined-sensor models |
| 0-5 V | A compatible voltage input | Reference connection, input range, cable arrangement and scaling | RK100-02 Wind Speed Sensor; RK110-02 Wind Direction Sensor; RK120-01 Combined Wind Speed and Direction Sensor |
| RS485 | A compatible digital logger, PLC or gateway | Protocol, device address, communication settings, registers and units | Options across the speed, vane and combined-sensor models |
For the RK100-01G Wind Speed Sensor, the pulse high level depends on its supply voltage. Check that against the receiver's permitted input level. Do not reuse another anemometer's pulse-to-speed coefficient without checking the ordered sensor documentation.
The RK120-01 Combined Wind Speed and Direction Sensor specifies an NPN pulse option for wind speed only. Specify how direction will be acquired as well. Its RS232 option may also be relevant where the receiving equipment requires that interface.
Treat the listed interfaces as configuration options, rather than assuming every output operates simultaneously. Obtain the pinout, power requirements and communication or scaling documents for the complete order.
Separate cup and vane sensors allow each measuring element to be selected and serviced individually. Include both mounting positions and both signal paths in the design.
A combined assembly such as the RK120-01 Combined Wind Speed and Direction Sensor groups speed and direction in one mechanical unit. It can simplify the mounting arrangement, but both measurements still need compatible acquisition channels and the correct output configuration.
Choose a position that represents the intended measurement and avoids unnecessary obstruction from buildings, trees, equipment and the mounting structure. Follow the project's specified height and exposure requirements; a weather-station reference measurement and an equipment-mounted monitor serve different purposes.
Use the specified bracket or flange arrangement, keep the assembly correctly level and leave the rotating components clear. Account for cable support, weatherproof connections, grounding and any required surge protection.
Use the fixed reference mark described in the relevant installation instructions:
These instructions concern the fixed installation marks, not holding the freely moving vane in one direction. After mounting, verify the reported direction against a known heading using the project's direction reference and the ordered sensor instructions.
A sensor connected to a logger may be sufficient for a recorded weather dataset. Operators who need to see wind speed locally or receive configured warnings need the appropriate display and control functions as well.
Documentation for the RK150-01 Wind Speed Display Controller describes a wind speed sensor and display-controller system, with adjustable warning and alarm settings and two corresponding relays. The warning setting must be lower than the alarm setting.
Select the sensor connection, cable length, power supply, controller location and required relay functions as a complete arrangement. The sensor's output options should not be assumed compatible with the RK150-01 controller without confirmation of the matched system.
For equipment monitoring, determine action thresholds from the equipment requirements and the site's approved operating procedures. The controller's adjustable range does not establish a universal safe operating wind speed. Include display, signal-loss and warning/alarm function checks during commissioning.
Inspect cups, arms, vanes, bearings, mounting hardware, cables and connectors at intervals appropriate to the site. Look for damage, contamination, unusual bearing noise or restricted movement. Mechanical deterioration can affect low-wind behaviour before the system stops reporting values.
Keep cleaning and service methods consistent with the product instructions. Do not change cup geometry or apply an unapproved lubricant as a substitute for proper servicing. Arrange manufacturer support for repairs or component replacement where required.
A functional check confirms that a rotor, output or alarm responds. It does not establish wind-speed accuracy. Where calibration evidence is required, request the appropriate wind-tunnel calibration, applicable method, uncertainty information and reporting conditions for the instrument and project.
Keep records of installation, configuration, checks and repairs. Recheck performance after work that may affect the measuring mechanism or its calibration relationship.
Before requesting a model recommendation or quotation, prepare:
The cup rotor measures wind speed. Add a wind vane for direction or choose a combined cup-and-vane assembly such as the RK120-01 Combined Wind Speed and Direction Sensor, with both outputs specified.
No. Starting threshold describes the onset of rotor or vane movement. Confirm the instrument's specified measuring performance in the low-wind region needed by the application.
No. RS485 is an electrical interface. Confirm the protocol, settings and register documentation for the ordered device and receiver.
No. Its specification lists 0-45 m/s for current or voltage output and 0-70 m/s for pulse, RS485 or RS232. The pulse option measures speed; direction acquisition must be specified separately.
No. The RK110-01G Wind Direction Sensor specifies north for its index mark, while the RK110-02 Wind Direction Sensor and RK120-01 Combined Wind Speed and Direction Sensor specify south for their installation arrow. Use the correct instructions for the model.
Compatibility must be confirmed for the complete sensor-and-controller configuration. Specify the sensor, signal, supply, cable arrangement and required display or relay functions together.
Share your application, required wind measurements, expected range, site conditions and receiving equipment with RIKA SENSOR. Our team can review a dedicated cup sensor, a separate or combined wind-direction arrangement, or a matched speed display-and-alarm system.
Include the mounting and maintenance requirements so the recommendation covers the complete measuring point.