Rika Sensor is a weather sensor manufacturer and environmental monitoring solution provider since 2010
PRODUCT DESCRIPTION
The RKL-10 Electromagnetic Flowmeter measures the volumetric flow of conductive liquids based on Faraday’s law of electromagnetic induction. Its unobstructed flow path contains no moving parts, helping reduce mechanical wear and maintenance. Low-frequency excitation and digital signal processing support stable measurement and strong interference resistance. The backlit LCD provides a clear local display, while output options include 4-20 mA, frequency/pulse and RS485. Available in integrated and split configurations, it features empty pipe detection and electrode contamination diagnostics. Typical applications include water treatment, chemical processing, metallurgy, food and pharmaceutical production, and liquid cooling.
SPECIFICATIONS
Item | Technical Specification |
Maximum flow velocity | 15 m/s |
Nominal diameter (DN) | 3, 6, 10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, 1800, 2000, 2200, 2400, 2600, 3000 |
Accuracy level | ±0.5%, ±1.0%, ±1.5% |
Rated pressure | DN3–300: 1.6 MPaDN350–1000: 1.0 MPaDN1200–2000: 0.6 MPaDN2200–3000: 0.2 MPa |
Electrode form | Standard, Scraper-type, Insertion-type, Grounding Electrode |
Electrode material | 316L stainless steel, HC, HB, Titanium, Tantalum, Tungsten Carbide, platinum/iridium alloy |
Flange material | Carbon steel |
Grounding ring material | 304, 316L, HC, HB, Titanium, Tantalum |
Inlet protection ring material | Carbon steel, stainless steel |
Ingress protection | IP65 (integrated, split type host)IP68 (split type sensor) |
Explosion-proof standard | Integrated: explosion-proof type, intrinsic safety typeSplit type: explosion-proof box can be separately installed |
Connecting cable | The split type flowmeter requires a dedicated connecting cable with a length of ≤ 100 meters; Standard 10 meters |
Power supply | AC: 85–250V, 50/60HzDC: 20-36V |
Operation and display | 4-button keypad, High-resolution backlit LCD, Self-diagnostic function |
Output signal | 4-20mA, 0-5kHz frequency/pulse, RS485 |
DIMENSION
Nominal Diameter (DN) | L (mm) | H1 / H2 (Ref.) (mm) | W (mm) | K (mm) | n-d | kg (Ref.) |
15 | 200 | 275/240 | 95 | 65 | 14-4 | 9 |
20 | 200 | 285/250 | 105 | 75 | 14-4 | 9.5 |
25 | 200 | 295/260 | 115 | 85 | 14-4 | 10 |
32 | 200 | 315/280 | 135 | 100 | 18-4 | 11 |
40 | 200 | 325/290 | 145 | 110 | 18-4 | 12 |
50 | 200 | 340/305 | 160 | 125 | 18-4 | 14 |
65 | 250 | 360/325 | 180 | 145 | 18-4 | 15 |
80 | 250 | 375/340 | 195 | 160 | 18-8 | 16 |
100 | 250 | 395/360 | 215 | 180 | 18-8 | 19 |
125 | 250 | 425/390 | 245 | 210 | 18-8 | 23 |
150 | 300 | 460/425 | 280 | 240 | 23-8 | 27 |
200 | 350 | 515/480 | 335 | 295 | 23-12 | 45 |
250 | 450 | 585/550 | 405 | 355 | 25-12 | 67 |
300 | 500 | 640/605 | 460 | 410 | 25-12 | 77 |
350 | 550 | 680/645 | 500 | 460 | 23-16 | 92 |
400 | 600 | 745/710 | 656 | 515 | 25-16 | 104 |
450 | 600 | 795/760 | 615 | 565 | 25-20 | 120 |
500 | 600 | 850/815 | 670 | 620 | 25-20 | 135 |
600 | 600 | 960/925 | 780 | 725 | 30-20 | 150 |
700 | 700 | 1075/1040 | 895 | 840 | 30-24 | 220 |
800 | 700 | 1190/1150 | 1110 | 950 | 34-24 | 280 |
900 | 900 | 1290/1255 | 1120 | 1050 | 34-28 | 310 |
1000 | 900 | 1400/1365 | 1220 | 1160 | 34-28 | 360 |
1200 | 1200 | 1585/1550 | 1405 | 1320 | 33-32 | 550 |
1400 | 1400 | 1810/1775 | 1630 | 1560 | 36-36 | 700 |
1600 | 1600 | 2010/1975 | 1830 | 1760 | 36-40 | 850 |
1800 | 1800 | 2225/2190 | 2045 | 1970 | 39-44 | 1000 |